What size boiler do I need?

The short answer

Most homes with a combi boiler need 24 to 34 kW: 24 to 27 kW for 1 to 2 bedrooms and 28 to 34 kW for 3 to 4, on the guide Vaillant publishes. A system or regular boiler for the same homes is smaller, 9 to 18 kW and 18 to 26 kW, because it stores hot water. These are general guides: the installer's heat loss calculation decides the size, and a boiler bigger than you need wastes money.

What size combi boiler do I need?

24 to 27 kW for 1 to 2 bedrooms, 28 to 34 kW for 3 to 4, on Vaillant's guide.

BedroomsRadiatorsBathroomsRecommended combi output
1 to 2Up to 10124 to 27 kW
3 to 410 or more2 to 328 to 34 kW
More than 420 or moreMore than 323 to 43 kW
Read the detail

Most homes with a combi need 24 to 34 kW: 24 to 27 kW for 1 to 2 bedrooms with one bathroom and up to 10 radiators, and 28 to 34 kW for 3 to 4 bedrooms with 2 to 3 bathrooms, on the guide the boiler maker Vaillant publishes.

Vaillant, "What size boiler do I need?", read 5 October 2026; the page is not dated. Vaillant calls these general guidelines and recommends asking a heating engineer. Its figure for the largest homes is as published, 23 to 43 kW; Viessmann gives 35 to 43 kW for a house with about twenty radiators.

Viessmann, another maker, gives a similar picture by radiators: an average three or four bedroom house has about ten radiators and would need a 24 to 30 kW combi, a larger house with more radiators and bathrooms 30 to 35 kW, and a house with as many as twenty radiators 35 to 43 kW, or better, a system boiler. It says that with more than four bedrooms and three bathrooms a combi is unlikely to be the best choice.

What size system or regular boiler do I need?

9 to 18 kW for 1 to 2 bedrooms, 18 to 26 kW for 3 to 4: smaller, because the hot water is stored.

BedroomsRadiatorsBathroomsRecommended system or regular output
1 to 2Up to 1019 to 18 kW
3 to 410 or more2 to 318 to 26 kW
More than 420 or moreMore than 327 to 40 kW
Read the detail

A system or regular (heat-only) boiler is smaller for the same home: 9 to 18 kW for 1 to 2 bedrooms and 18 to 26 kW for 3 to 4, on Vaillant's guide, because it heats a cylinder of stored water ahead of time and does not have to heat water on demand.

Vaillant, "What size boiler do I need?", read 5 October 2026: the same guide gives one table for system boilers and regular boilers, which Vaillant also calls open vent boilers.

Viessmann puts the heat load of an average home at around 10 to 20 kW, which is why these boilers can be sized smaller than a combi. With stored hot water the size of the cylinder matters as much as the boiler: ask the installer to size both for the number of people and bathrooms.

Why a combi is bigger than the heating needs

A combi is sized for hot water on demand. A typical 3 bed semi needs about 9 kW of heating.

Home, typical insulationHeat needed a yearHeating loadCombi size on the makers' guides
2 bed flat6,390 kWhabout 6 kW24 to 27 kW
2 bed terrace6,300 kWhabout 5.5 kW24 to 27 kW
3 bed semi9,900 kWhabout 9 kW24 to 30 kW
4 bed detached house13,140 kWhabout 12 kW24 to 30 kW
2 bed bungalow8,280 kWhabout 7.5 kW24 to 27 kW
Read the detail

A combi is sized for hot water, not for the radiators. Our heat model puts the heating load of a typical 3 bed semi at about 9 kW, yet the makers' guides suggest a 24 to 30 kW combi for it, because a combi must heat cold mains water to a hot tap's temperature the moment the tap opens.

Heat needed a year is the gas a typical gas heated home of that type uses (DESNZ National Energy Efficiency Data-Framework 2026) at a boiler efficiency of 90%. Heating load is that heat spread over 1,100 hours a year at full output, the rule our heat model uses to size a heat pump, so treat it as a guide to scale, not a design figure. Combi sizes are Vaillant's guide for 1 to 2 bedrooms and Viessmann's for a three or four bedroom house.

Viessmann says as much: a combi's capability is expressed as how much water it can heat a minute, for example 12 litres a minute at a 35 degree rise, and the higher the flow you want for baths and showers, the larger the boiler. Combis end up oversized for the heating as a result, it says, which makes them less efficient at heating the home than a system or regular boiler.

Why oversizing wastes money

It costs more to buy and can waste gas. Viessmann says a bigger boiler than you need is not recommended.

Read the detail

A boiler bigger than the home needs costs more to buy and more to run. Viessmann says choosing a bigger boiler than you need is not recommended: it could result in wasted energy and is likely to leave you paying more than you need to for gas. Too big, it says, and the boiler may use too much energy heating water you are not going to use; too small, and you may run out of hot water or be left with a house that will not heat up properly.

It costs more upfront too. Heatable, an online installer, lists output as one of the things that set the price: bigger homes need a boiler with a higher output, which means a higher price. Its installed prices run from £1,800 to £3,500 for a like-for-like combi swap to £3,000 to £4,500 for a premium model.

The old habit was to add size to make up for heat lost through the roof, walls and windows. Viessmann says that with modern boilers this is no longer the advice. If a home loses a lot of heat, the fix that lasts is insulation: see our insulation savings calculator.

A heat loss calculation decides the size

The installer's heat loss calculation, from floor area, radiators, windows and insulation.

Read the detail

The tables above are a starting point. The right size comes from a heat loss calculation by the installer, which Viessmann calls a much better way to choose than the size of the house: it takes in the floor area, the number of radiators, the number and type of windows and the insulation, and works out how much heat the house loses on the coldest day of the year.

Two homes with the same bedrooms can differ a good deal. In our heat model a well insulated 3 bed semi needs a heating load of about 7.5 kW and a poorly insulated one about 10 kW. Ask each installer how they arrived at the size they quote, and be wary of one who matches the old boiler's output without checking.

Bathrooms, hot water and water pressure

One bathroom usually suits a combi; three or more, a system boiler. Mains pressure matters too.

BathroomsHeatable's rule of thumb
One bathroomUsually suitable for a combi
Two bathroomsA combi or a system boiler, depending on hot water demand
Three or more bathroomsA system boiler often makes more sense
Read the detail

How much hot water you use at once decides the type, and the type decides the size. One shower at a time suits a combi. Two running together, or a bath filling while someone washes up, favours the stored hot water of a system or regular boiler.

Heatable, "New boiler installation costs 2026", updated 25 September 2026. The Energy Saving Trust gives the same advice in words: combis are less suitable for houses with several bathrooms or high hot water use.

Water pressure matters as well. A combi has to be big enough for the water passing through it, Viessmann says, and some older homes have poor mains pressure, which can change the type and size of boiler that suits. Our guide to combi vs system boiler covers which type suits which home.

Boiler size and cost for your home

See the boiler pages by type of home, or price a swap in the calculator.

Read the detail

For the type and size that usually suit a particular home, with its gas use, the saving and the payback, see our pages on a new boiler for a 2 bed flat, 2 bed terrace, 3 bed semi, 4 bed detached house and bungalow. The new boiler cost calculator prices a swap or a conversion, and our new boiler cost guide covers what a quote should include.

Frequently asked questions

What size boiler do I need for a 3 bedroom house?

With a combi, about 24 to 30 kW for a three or four bedroom house with about ten radiators, according to Viessmann, and 28 to 34 kW on Vaillant's guide for 3 to 4 bedrooms with 2 to 3 bathrooms. A system or regular boiler for the same home is about 18 to 26 kW.

Is a 30 kW boiler too big for my house?

For heating alone, usually yes: Viessmann puts the heat load of an average home at around 10 to 20 kW. A combi is rated higher because it heats water on demand, so a combi of that size is normal for a three or four bedroom house. A system boiler of that size would suit only a large one.

What happens if a boiler is too big?

Viessmann says an oversized boiler could waste energy and is likely to leave you paying more than you need to for gas. A higher output also costs more to buy.

How many radiators can a combi boiler run?

On the makers' guides, up to 10 radiators with a 24 to 27 kW combi and 10 or more with 28 to 34 kW. Viessmann says a house with as many as twenty radiators may need a 35 to 43 kW combi, or would be better with a system boiler.

Who decides what size boiler I need?

The installer, from a heat loss calculation for your home and your hot water use. The published tables are general guidelines, and Vaillant recommends consulting a heating engineer before deciding.

Data sources

Vaillant and Viessmann for sizes, Heatable for prices, our heat model for heating loads.